<LOGO>
FM Transmitter Measurement Report
Created: 2024-08-26 17-01-49
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 56 dBuV SANDELS
Pilot RDS Phase Difference
6.6 kHz 5.8 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 59 kHz 14402 3,6592
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,5 dBr 2,23 dBr 4,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 9 --:--
RT
-
AF EON
92.0, 94.7, 98.5, 106.3, 107.5 MHz -
FM Scope Max at: 59 kHz MIN: 13 kHz % above 76 kHz: 3,6592 Acquired: 2024/08/26 17.00.45 Total samples: 14402 Equivalent time: 0:12:00 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: 4,0 dBr MIN: 0,5 dBr AVE: 2,23 dBr % above 12,2 dBr: 0,0 Last value: 3,0 dBr (2024/08/26 17.00.45) 16.46 16.48 16.50 16.52 16.54 16.56 16.58 17.00 0 2 4 Pm [dBr]